structure
and to be metal clad with #26 gauge white
pre-painted stucco embossed steel front
and back with reinforcement for hard-ware attachment.
Frame to be constructed of
aircraft alloy aluminum extrusion with white painted
finish.
Door leaf to be filled with 4" (101.6mm) of Jamifoam non-CFC
polyurethane insulation with an R
value of 28 at 40°
F (4½°C). Frame to be
insulated with polystyrene
inserts.
Adjustable gasket at sides and head of door
frame
to be polyester reinforced. Sill gasket on
bottom of door to be sweep type.
Hardware and track to have protective coating against corrosion Doors to
be equipped
with chain
operated top latch. Galvanized 3"
(76.2mm) track formed of 12 Ga. steel to be adjust-able for
tight gasket seal. Wedge-in track design
gives "down and in" motion to assure tight
seal without cams or levers.
Door to be operable from front side only.
(ARCHITECT
NOTE: Specify if back operation required.)
FREEZER DOOR SPECIFICATIONS:
Freezer door specifications to be same as cooler door except for these
substitutions and additions:
Supply where indicated on plans Jamison Mark IV ™ Manual Vertical
Sliding Freezer.
Provide Frostop heater cables in the sides, head, and bottom of door.
Complete device to be assembled, ready for connection to 120 volt, 60 Hertz,
single phase AC line (other voltages available)
SPECIAL NOTES:
Freezer Door is designed for installation
in
warm room with temperatures above +33°
F (½°C). If door must be
mounted in rooms with
temperatures of +32° F
(0°C) and below, contact BMIL
International.
When cold room temperature is below -2
0°F
(-29°C), or temperature
difference is more than 90°F
(50°C), contact BMIL International.
If freezer door must be mounted in freezer room, please contact BMIL
International for recommendations.
Consult BMIL International before quoting on applications in
processing areas where hot or caustic washdown solutions are used.
OPTIONS: (SPECIFY which options are desired):
Back Operation
a. With locking provisions.
b. Without locking provisions.
Locking provisions:
a. On front-hasp and staple, no back
operation.
b. On front-hasp and staple, w/back operation.
c. On back-key cylinder w/back operation. Manual Door only.
d. On back-hasp and staple, w/front operation.
Power Door only.
e. On back-hasp and staple, no front operation. Power Door only.
M.I.D. requirements.
Power Operation:
a. Factory assembled and tested.
b. Provisions for future installation.
Other Finishes:
a. Galvanized Painted Steel (specify color)
b. Stainless Steel
c. Stucco Embossed Aluminum
d. Galvanized Steel
View Windows: (contact BMIL International for specific
recommendations.)
12" x 14" (304.8mm x 355.6mm) sealed
glass unit.
a. Cooler Door-2 layer, 1" (25.4mm) thick.
b. Freezer Door-3 layer, 1" (25.4mm) thick with 120
V.A.C. heat film (other voltages available).
Jambs.
Inside trim.
6" (152.4mm) of insulation for freezer door (R value