Modular Structures Architectural Specifications
1.
SCOPE - These specifications cover BALLY
MODULAR STRUCTURES and related equipment and accessories, manufactured or
supplied by Bally
2. MANUFACTURERS' INSTALLATION INSTRUCTIONS - Contractor shall furnish
to owner instructions detailing assembly of the building, wiring diagrams,
operating and maintenance instructions, and other data pertaining to proper
upkeep and operation of the building. Installation, start-up and testing shall
be carried out in accordance with the equipment manufacturers' published
instructions.
3. WARRANTY - 10 YEARS - The manufacturer shall warrant that Bally
manufactured components are free from defects in material or workmanship under
normal use and service. The warranty shall not apply to equipment which has been
subjected to any accident, alteration, abuse, misuse or improper installation
and shall not include any labor charges for replacement or repair of defective
panels, parts or other equipment. Review all warranties for specific details
pertaining to coverage.
4. PERFORMANCE SPECIFICATIONS
- Because requirements vary with individual site locations and local
construction regulations, review and approval of all such plans must be the
responsibility of an engineer familiar with the circumstances of the individual
installation. All work and materials shall be in full accordance with local
and/or state ordinances, and with any other prevailing rules and regulations
regarding potentially hazardous equipment or locations. Bally Modular Structures is not responsible for furnishing items
required by the regulations, but not specified or shown on the drawing or
contained in the specifications.
A.
The urethane foam core of the panels shall be certified by Underwriters
Laboratories as having flame spread of 25 or lower and smoke generation of 450
or lower when tested in accordance with UL Standard 723 (ASTM Standard E-84).
B. The foam core of the panels shall
be tested in accordance with ASTM Standard D- 1929 to determine the
self-ignition temperature.
C. These panels shall be listed by
Factory Mutual as having been tested in accordance with the Factory Mutual Full
Scale Corner Test, Procedure 4880.
D.
All buildings have been designed for Seismic Zone IV with a roof live load of 30
psf, a roof dead load of 4 psf and a wind load of 90 mph. (Specify other design
loads if required).
E. Panels shall be tested in
accordance with ASTM Standards E-72, E-455 and E- 564 for determination of the
structural characteristics of the panel system.
F. The foam insulation shall be
tested in accordance with ASTM Standard C-177 to evaluate the insulation
performance of the material.
G. Certification of the above
performance specifications must be provided by the indicated independent testing
laboratory or by any other independent agency recognized by the major model
building code agencies: UBC, BOCA or the SBBC.
H. Foam insulation manufacturer shall
be licensed by the State of California Board of Thermal Insulation.
5.
PRODUCT SPECIFICATIONS - Buildings
shall be manufactured by Bally Modular Structures.
A.
Panels shall consist of interior and exterior metal skins formed with steel dies
and roll-forming equipment and checked with gauges for uniformity and accuracy.
The metal skins shall be placed into steel molds and liquid urethane injected
between them. For extra rigidity, the exteriors of all vertical panels, except
corners, shall have vertical grooves spaced on 5-3/4" centers. Panels over
12 feet high will also have interior vertical grooves. Urethane shall be
foamed-in-place (poured, not frothed) and, when completely heat-cured, shall
bond to the metal skins to form a rigid 4"-, 5"-, or 6"-thick
insulated panel. Panels shall contain 100-percent urethane insulation and have
no internal wood between the skins. To insure tight joints, panel edges must
have foamed-in-place tongues and grooves with a flexible vinyl gasket also
foamed-in-place on the interior and exterior of all tongue edges.
B. All panels except comer panels
shall be made in 23" and 46" widths, and shall be fully
interchangeable for easy assembly. Panels 11- 1/2" or 34-1/2" wide are
to be furnished only when required to fit the allocated space. To assure correct
alignment and maximum strength, comer panels shall be 90 degree angles with
exterior horizontal dimensions of 12" on each side.
C. Panels shall be equipped with Bally
"Speed-Lok®" joining devices. The distance between locks shall
not exceed 46". Each locking device shall consist of a cam-action, hooked
locking arm of a replaceable type placed in one panel, and a steel rod precisely
positioned in the adjoining panel, so that when the lacking arm is rotated, the
hook engages over the rod and draws the panels tightly together with carn
action. When tested, the tensile strength of the Speed-Lok connection shall not
be less than 750 pounds. The locking arms and steel rods shall be housed in
individual steel pockets set into the pockets. Pockets on one side of the panel
shall be connected to pockets on the other side, in width, by the use of steel
straps set into the insulation. When panels are joined together - these straps
shall form "perimeters of steel," with lock-to-lock-to-lock
connections for extra strength. An aligning device shall be provided in at least
one "Speed-Lok" pocket for every vertical panel. Press-fit caps shall
be provided to close wrench holes.
D.
EXTERIOR FINISH
1. .026” embossed galvanized steel
with sand tan polyester painted finish (24 ga.)
2. .026” galvanized steel with
white polyester painted finish (24 ga.)
3. Profile finish .022” embossed
galvanized steel with white polyester painted finish.
4. Pebble Beach Sandex (other colors
available).
5. .026” bright embossed galvanized
steel (24 ga.).
6. .038” stucco embossed aluminum.
7. .030” stainless steel (22 ga.)
8.
Other finishes available. Contact BMIL International, Inc. for additional information.
E. INTERIOR FINISH - Same as above except 3,4. Bally floor panels are
provided with .073” Galvanized (14 gauge) or .060” stainless steel (16
gauge).
F. BUILT-IN INSULATED FLOORS
- The floor shall be
constructed on the job site. It shall consist of a depressed, reinforced
concrete sub slab. Slab urethane shall be built into this depressed slab. Wall
panels shall be fastened to this floor. Adequate drainage and ventilation (or
other heat source) must be provided beneath and around all construction.
6.
4"
-
THICK HINGED ENTRANCE DOOR PANELS
A. Entrance openings listed in the
following size schedule shall be provided in 46"-(or 69"-) wide
panels. The door is an infitting flush-rnounted type. Construction of both panel
and door shall be as stated in paragraph 5. A thermoplastic gasket with a
magnetic core shall be mounted on the top edge and along both sides of the door.
The magnetic force of the gasket shall keep the door closed and the gasket shall
form a tight seal. The bottom edge of the door shall contain a flexible,
dual-blade wiper gasket. Construction of the door panel shall include a heavy,
"U" channel type, reinforced steel frame around the entire perimeter
of the door opening to prevent racking or twisting. Doors are available in the
following clear opening sizes:
30" x 78", 30" x 84", 34" x 66", 34" x
78", 34" x 84", 42" x78", 48" x 78", 48"
x 84", 60" x 78", 60" x 84".
The numbers of doors, their location and direction of swing is specified on the
plans.
B. Hardware for standard hinged entrance doors. (Doors with
30"-34"- and 42"-wide openings.) All hardware shall be surface-rnounted,
satin-finish.
DOOR
HINGES:
Each door shall have two hinges of the spring-loaded, self-closing type, with
plated steel pins and Delrin cam-type bearings.
DOOR LATCH: The latch shall be
designed to open the door easily by breaking the magnetic force of the door
gasket. The latch shall have a cylinder lock with provisions for padlocking. It
shall also include an inside safety release handle to prevent anyone from being
locked inside.
C.
Hardware for hinged entrance door (Doors with 48" and 60" openings) -
All hardware to be surface mounted.
LATCH
AND STRIKE ASSEMBLY:
The latch and strike assembly shall be satin- finish. The latch shall be made to
accommodate a padlock but must include an inside safety release mechanism to
prevent anyone from being locked inside.
HINGES:
The hinges shall match the latch in general finish and design. Blades shall be
no less than 9" long and hinges shall be of the up-lift type with Delrin
cams on 3/8" dia. pins. (60"-wide doors are provided with three
hinges.)
D.
Weatherproof shield
- All doors for outdoor structures shall be supplied with a metal shield above
the door to divert rain and snow from the door opening.
E.
Sill plates - An
extruded aluminum sill plate shall be provided on applications without floors.
7.
2"
- THICK HINGED ENTRANCE DOORS
A.
Insulation
shall consist of a full 2"-thick foam urethane insulation core. Heavy-gauge
matching- metal jambs must be designed to fit prefab panels perfectly without
the use of any interior framing. Jamb members shall attach to panels with sheet
metal screws. The door shall be supplied with weather stripping and a wiper
gasket. observation windows, 10" x 10" or 24" x 36", are
available as factory-installed options and must be specified if required.
Entrance openings are available in the following clear opening sizes: 36" x
84" for single doors; and 48" x
84", 60" x 84", and 72" x 84" for double doors.
B. Hardware for Doors - Hardware
shall be cylindrical lockset with satin stainless steel finish. Pin tumbler
cylinder can be keyed differently, keyed alike or master keyed.
C. Door Hinges - Each door shall have
(3) tamper-proof pinned butt hinges.
D. Weatherproof Shields - All doors
for outdoor structures shall be supplied with a metal shield above the door to
divert rain and snow from the door opening.
E. Sill plates
- An extruded aluminum sill plate shall be provided on outdoor buildings
which are furnished without floors.
8.
MANUAL OVERHEAD SLIDING DOORS - Doors shall be steel
sectional overhead type. Sections shall be 2" thick, roll-formed from
hot-dip galvanized steel. Finish shall be painted on the exterior, a coat of
baked-on polyester enamel over epoxy primer. Interior finish is baked-on
polyester enamel. Exterior lock shall be five-pin tumbler cylinder with night
latch and steel bar engaging track. Interior locking is dead bolt with hole to
receive padlock. Bottom of door is to have flexible U-type vinyl seal in
aluminum retainer attached to section with 1/4" bolts.
9. WINDOWS - Windows shall be
30" x 30" in size and be of the "fixed" type. Each shall be
made as a complete unit and shall consist of two panes of glass separated by a
sealed air space. The metal trim shall be of the same finish as the remainder of
the panel.
10.
PARTITIONS - Insulated metal - clad
partition panels shall be provided when compartments are to be separated.
11.
PREFAB SECTIONAL METAL ROOF
- (For buildings installed outdoors and not exceeding 34'7" in width - can
be any length) A prefab sectional roof shall be furnished for the building to
provide a waterproof covering for ceiling panels. It shall be made of
.038”stucco-embossed aluminum.
12. SUPPORTING STEEL - Structural
steel of sufficient size and strength shall be supplied to support ceiling
panels and wall panels where necessary. If the building is installed outdoors,
snow load and wind load must be specified to determine steel sizes. (Where
required, all sizes, types and weights of steel, as recommended by the
manufacturer / supplier, shall be submitted by the architect to state or local
building authorities for approval.)
13.
GUTTERS AND DOWNSPOUTS
Rain gutters and downspouts shall be provided to match exterior finish of
building.
14.
LOUVERS - Louvers are fixed type with insect screen, factory
installed. Operable louvers are available at special request.
15. ALTERNATE AND OPTIONAL EQUIPMENT
A.
Type M Bullet Resistant - Steel plate shall be foamed in panel which will absorb
fire from calibers up to a .30-06 rifle.
B. .073” Galvanized Exterior Metal
14 Gauge - Exterior skins can be furnished in 14-ga. steel. This design will
absorb fire from calibers up to a .22 rifle.
C.
Air Conditioners/Heaters - Specify BTU requirements for heating or cooling
loads.
16. SPECIFY BY NAME - To assure that
specifications prepared from this guide will be complied with fully, we suggest
that the following paragraph be included:
The modular structure shall be as
manufactured by Bally
to protect the client's interests, no substitutions will be accepted
unless by specific approval.